Comparison Between Thermo Luminescence Dosimeter and Planning System Dose Calculation in The Brain and Spinal Cord Tumour

  • Ehab A Hegazy Delta University for science and technology
Keywords: Spinal cord, radiotherapy, luminescence

Abstract

Radiotherapy of Spinal cord and brain tumor requires High care due to considerable changes in the white matter of the brain, which consequently lead to a reduction of patient learning and mental skills. It is considered a very critical tumor due to high sensitivity of gross volume location and normal tissues surrounding it, including eye, heart, plate thyroid, and testis. XiO planning systems, TLD dosimeter found in Mansoura university oncology department, CMS XIO USA TPS were compared using electron and photon beams with different energies at a different site in target volume and organs at risk. We conclude that regular calibration of planning systems and direct measurement of the dose delivered to main target and organs at risk should be done to avoid the difference between XiO planning systems and direct measurement by TLd.

Downloads

Download data is not yet available.

Author Biography

Ehab A Hegazy, Delta University for science and technology

Department of basic science, Faculty of engineering, Delta University for science and technology, Mansoura, Egypt

References

Spirou, S., Basini, M., Lascialfari, A., Sangregorio, C., & Innocenti, C. (2018). Magnetic hyperthermia and radiation therapy: Radiobiological principles and current practice. Nanomaterials, 8(6), 401.?

Mulhern, R. K., Palmer, S. L., Reddick, W. E., Glass, J. O., Kun, L. E., Taylor, J.,& Gajjar, A. (2001). Risks of a young age for selected neurocognitive deficits in medulloblastoma are associated with white matter loss. Journal of Clinical Oncology, 19(2), 472-479.?

Hegazy EA. Study of output difference of two different ionization chambers for large fields used in radiotherapy.JOURNAL OF ADVANCES IN PHYSICS. 2017 Jun 1;13(5):4901-7.

Han, K., Cheung, P., Basran, P. S., Poon, I., Yeung, L., & Lochray, F. (2010). A comparison of two immobilization systems for stereotactic body radiation therapy of lung tumors. Radiotherapy and Oncology, 95(1), 103-108.?

Brock, J., Bedford, J., Partridge, M., McDonald, F., Ashley, S., McNair, H. A., & Brada, M. (2012). Optimizing stereotactic body radiotherapy for non-small cell lung cancer with volumetric intensity-modulated arc therapy—a planning study. Clinical Oncology, 24(1), 68-75.?

Olko, P. (2010). Advantages and disadvantages of luminescence dosimetry. Radiation Measurements, 45(3-6), 506-511.?

Low, D. A., Moran, J. M., Dempsey, J. F., Dong, L., & Oldham, M. (2011). Dosimetry tools and techniques for IMRT. Medical Physics, 38(3), 1313-1338.?

Siddique, R., Uddin, Z., & Hussain, M. (2012). Dosimetric evaluation and verification of external beam 3-D treatment plans in humanoid phantom using thermo luminescent dosimeters (TLDs). Journal of Basic & Applied Sciences, 8, 690-695.?

Mollazadeh, M., Allahverdi, M., Allahverdi Pourfallah, T., Riahi Alam, N., & Ay, M. (2010). Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation. Iranian Journal of Medical Physics, 7(2), 81-93.?

Lu, L. (2014). Dose calculation algorithms in external beam photon radiation therapy. International Journal of Cancer Therapy and Oncology, 1(2).?

Koeck, J., Abo-Madyan, Y., Lohr, F., Stieler, F., Kriz, J., Mueller, R. P., ... & Eich, H. T. (2012). Radiotherapy for early mediastinal Hodgkin lymphoma according to the German Hodgkin Study Group (GHSG): the roles of intensity-modulated radiotherapy and involved-node radiotherapy. International Journal of Radiation Oncology* Biology* Physics, 83(1), 268-276.?

Ezzell, G. A., Burmeister, J. W., Dogan, N., LoSasso, T. J., Mechalakos, J. G., Mihailidis, D., ... & Shi, J. (2009). IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Medical Physics, 36(11), 5359-5373.?

Zani, M., Bucciolini, M., Casati, M., Talamonti, C., Marinelli, M., Prestopino, G., ... & Verona?Rinati, G. (2013). A synthetic diamond diode in volumetric modulated arc therapy dosimetry. Medical Physics, 40(9), 092103.

Kamomae, T., Oita, M., Hayashi, N., Sasaki, M., Aoyama, H., Oguchi, H., ... & Naganawa, S. (2016). Characterization of stochastic noise and post-irradiation density growth for reflective-type radiochromic film in therapeutic photon beam dosimetry. Physica Medica, 32(10), 1314-1320.?

Published
2019-08-07
How to Cite
Hegazy, E. A. (2019). Comparison Between Thermo Luminescence Dosimeter and Planning System Dose Calculation in The Brain and Spinal Cord Tumour. JOURNAL OF ADVANCES IN PHYSICS, 16(1), 272-279. https://doi.org/10.24297/jap.v16i1.8375
Section
Articles